Описание

  • Escape release on the rear
  • With door monitoring contact
Approach direction Horizontal and vertical Can be adjusted in 90° steps Solenoid operating voltage
  • AC/DC 24 V +10%, -15%
Guard locking type
    STP4Open-circuit current principle, guard locking by applying voltage to the guard locking solenoid. Release by spring force.
    Switching element
    4121Slow-action switching contact 2 NC + 1 NC / 1 NO (door monitoring contact)
    Escape release (C1993, long actuator shaft)This is used for manual release of guard locking from within the danger area without tools. With identification of On/Off position.
    Housing material Reinforced thermoplastic
    Weight
    Net 0,5 kg
    Ambient temperature -20 ... 55 °C
    Degree of protection IP67
    Mechanical life 1 x 106
    Contact material Silver alloy, gold flashed
    Switching principle Slow-action switching contact
    Installation orientation Any
    Number of door position NC contacts 1
    Number of door position NO contacts 1
    Number of guard lock monitoring positively driven contacts 2
    Connection
    3 x M20 x 1.5
    Approach speed
    max. 20 m/min
    Actuation frequency 1200 1/h
    Guard locking principle Open-circuit current principle
    Locking force Fmax 2500 N
    Locking force FZh 2000 N
    Retention force 20 N
    Extraction force 30 N
    Actuating force 35 N
    Insertion depth min.24,5 mm
    Electrical connection ratings
    Thermal rated current Ith 4 A
    Utilization category according to EN 60947-5-1
    AC-15 4A 50V
    DC-13 4A 24V
    Solenoid operating voltage
    AC/DC 24 V -15% ... +10%
    Short circuit protection according to IEC 60269-1
    (Fuse) 4A gG
    Rated insulation voltage Ui 50 V
    Rated impulse withstand voltage Uimp 2,5 kV
    Switching voltage
    Min. at 10mA 12 V
    Switching current
    Min. at 24V 1 mA
    Power consumption 8 W
    Solenoid duty cycle 100 %
    Connection cross-section 0,34 ... 1,5 mm?
    Other
    C number
    C1993 Escape release long
    Reliability values according to EN ISO 13849-1
    Monitoring of guard locking and the safety guard position
    B10D 5 x 106
    In combination with Actuator BETAETIGER-S-GT-SNMechanical values and environment
    Overtravel 5 mm
    ''