Описание

  • One cover for indicators
  • One operating mode selector
  • One illuminated pushbutton
  • including adhesive labels
  • Push-pull plug
  • Pre-assembled on mounting plates
  • Integrated Profinet RT switch
Profinet connection Connection via push-pull plugs according to IEC 61076-3-117 Profinet RT switch Point-to-point topology network structure due to integrated RT switch. Dimension drawing MGB: The MGB-System in use MGB: MGB Impact test MGB: Mounting left door, with escape release Mounting left door, without escape release Mounting right door, without escape release MGB: Deactivating guard lock monitor MGB: Activating guard lock monitor MGB: Activating release monitoring MGB: Change color-lens push button Dimension drawing Technical dataApprovals Mechanical values and environment
Housing material Reinforced plastic, die-cast zinc nickel-plated, stainless steel
Weight
Net 1,8 kg
Ambient temperature
At UB = 24V DC -20 ... 55 °C
Degree of protection IP54
Resilience to vibration In accordance with EN 60947-5-3
Installation orientation Any
Reaction time
Operating mode selector switch max.220 ms Switch-off time
Switching frequency 0,25 Hz
Connection Push-pull power
According to IEC 61076-3-117 variant 14, screened, Profinet I/O cable, at least cat. 5e Push-pull RJ45
Push-pull power
According to IEC 61076-3-117 variant 14, screened, Profinet I/O cable, at least cat. 5e Push-pull RJ45
Electrical connection ratings
Current consumption max.500 mA
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 0,5 kV
Maximum feed-in current in the connection block
X1, X2 max.4000 mA
EMC protection requirements In accordance with EN 61000-4 and EN 61326-3-1
Degree of contamination (external, according to EN 60947-1) 3
Connecting cable
Ethernet Profinet I/O cable, at least cat. 5e
Safety class III
Power supply X1
Operating voltage DC
L1 24 V DC -15% ... 10%
Auxiliary voltage DC
L2 24 V DC -15% ... +10%
Fusing
external min.1 A Slow blow
Power supply X2
Operating voltage DC
L1 24 V DC -15% ... 10%
Auxiliary voltage DC
L2 24 V DC -15% ... +10%
Interface, bus
Data interface
Data protocol
Bus protocol Profinet (IEC 61158 type 10)
Safety protocol Profisafe (IEC 61784-3-3)
Controls and indicators
Belegungsschema B2
Position 11
Ausfuhrung Cover for indicators
Einlegeschild
Extras
Farbe Red
Schaltelement
Position 12
Ausfuhrung Illuminated push buttons
Einlegeschild
Extras
Farbe white
Schaltelement 1NO
Position 13
Ausfuhrung Operating mode selector switch
Einlegeschild Entsichert / Unsecured , Sonderfunktion / Special function , Gesichert Zentral / Secured Central
Extras
Farbe
Schaltelement Code 2 of 3
Other
Product version number V3.23.3
Slide-in label
Anlage Gesichert
Quittieren
Line Secured
Line Reset
Reliability values according to EN ISO 13849-1
Selector switch evaluation
Category 4
Performance Level PL e
PFHD 4.1 x 10-8
Performance Level PL e
Category 4
Safety Integrity Level SIL 3 (EN 62061:2005)
Diagnostic Coverage (DC) 99
Mission time 20
''