Описание

  • Locking (without guard locking)
  • 3 pushbuttons (illuminated, wh, ye, bu)
  • Incl. adhesive labels
  • With cable entry
  • With plug connector M12 for enabling switch
  • Unicode
Guard locking type
MGB-L0...The bolt tongue in the handle module is moved into and out of the interlocking module by actuating the door handle. The door arm is not locked in the locked position.
Door hinge A mechanical door stop is permanently integrated into the evaluation module of the MGB. A marking on the stop makes adjustment easier. LED indicator The LED indicator indicates all important system and status information. Monitoring outputs
ODON when the door is closed
OTBolt tongue inserted in the evaluation module
OIDiagnostics, there is a fault
Pushbutton
S21 NO contact, white, illuminated
S31 NO contact, yellow, illuminated
S41 NO contact, blue, illuminated
Connection for enabling switch The device has an M12 plug connector for the direct connection of an enabling switch (e.g. ZSA, order no.: 110560). Adhesive labels Devices with adhesive labels have pre-formed recesses. The adhesive labels enclosed (standard size 12.5 x 27 mm) can be affixed in these recesses. Dimension drawing Dimension drawing Cable entry MGB: The MGB-System in use MGB: MGB Impact test MGB: Mounting left door, with escape release Mounting left door, without escape release Mounting right door, without escape release MGB: Changing series wiring (AR) to single wiring (AP) MGB: Deactivating guard lock monitor MGB: Activating guard lock monitor MGB: Activating release monitoring MGB: Change color-lens push button Dimension drawingDimension drawingCable entry Technical data Interlocking module MGB-L0-APA-AA6A1-S3-L-110547 (Order no. 110547) Mechanical values and environment
Housing material Reinforced plastic, die-cast zinc nickel-plated, stainless steel
Weight
Net 0,75 kg
Ambient temperature
At UB = 24V DC -20 ... 55 °C
Degree of protection IP65
Mechanical life 1 x 106
In case of use as door stop, and 1 Joule impact energy 0,1 x 106
Installation orientation Door hinge DIN left
Switching frequency 0,25 Hz
Connection
Plug connector SFF5
Cable entries M20x1.5
Electrical connection ratings
Utilization category according to EN 60947-5-2
DC-13 24V 200mA
Rated insulation voltage Ui 30 V
Rated impulse withstand voltage Uimp 1,5 kV
Degree of contamination (external, according to EN 60947-1) 3
Connection cross-section
(Rigid/flexible) with cable end sleeve according to DIN 46 228/1 0,25 ... 1,5 mm?
(Rigid/flexible) with cable end sleeve with collar according to DIN 46 228/1 0,25 ... 0,75 mm?
(Rigid/flexible) 0,13 ... 1,5 mm? (AWG 24 ... AWG 16)
Safety class III
Discrepancy time
Between FO1A and FO1B max.10 ms
Risk time according to EN 60947-5-3 max.350 ms
Transponder coding Unicode
Power supply UB
Operating voltage DC
UB 24 V DC -15% ... 10%
Current consumption
IUB max.80 mA
Power supply UA
Operating voltage DC
UA 24 V DC -15% ... 10%
Current consumption
IUA max.10 mA
Safety outputs FO1A, FO1B
Test pulses max.0,3 ms
Test-pulse interval min.100 ms
Type of output Semiconductor outputs, p-switching, short circuit-proof
Output voltage
UFO1A /UFO1B LOW 0 ... 1 V DC
UFO1A /UFO1B HIGH UB-2V ... UB V DC
Output current
Per safety output FO1A / FO1B 1 ... 200 mA
Monitoring outputs OD, OT, OL, OI
Type of output Semiconductor outputs, p-switching, short circuit-proof
Output voltage UA-2V ... UA V DC
Output current max.50 mA
Controls and indicators
Switching voltage UA V
Switching current 1 ... 10 mA
Breaking capacity max.0,25 W
Power supply LED 24 V DC
Other
Product version number V3.0.0
Slide-in label
3 pc. without marking
Automatik Start
Zutritt Anforderung
Storung Quittieren
Automatic Start
Access Request
Failure Reset
Reliability values according to EN ISO 13849-1
Monitoring of the position of the safety guard
Category 4
Performance Level PL e
PFHD 3.7 x 10-9
Mission time 20 y
Handle module MGB-H-AA1A1-L-106619 (Order no. 106619) Mechanical values and environment
Housing material Reinforced plastic, die-cast zinc nickel-plated, stainless steel
Weight
Net 1,00 kg
Ambient temperature -20 ... 55 °C
Degree of protection IP65
Installation orientation Door hinge DIN left
Other
Product version number V3.0.0
Components 110547 Interlocking module MGB-L0-APA-AA6A1-S3-L-110547
  • Locking (without guard locking)
  • 3 pushbuttons (illuminated, wh, ye, bu)
  • Incl. adhesive labels
  • With cable entry
  • With plug connector M12 for enabling switch
  • Unicode
106619 Handle module MGB-H-AA1A1-L-106619
  • Intelligent bolt tongue
  • Lockout bar
  • Door handle
''