Описание

  • Guard locking with guard locking monitoring
  • Can be connected in series with other AR devices (e.g. CES-AR and CET-AR)
  • Key-operated rotary switch (form L, 90°)
  • Two pushbuttons (illuminated)
  • With lens set, six pcs.
  • With plug connector RC18
  • With escape release
  • Unicode
  • Only numbered connecting cables may be used.
Guard locking type
MGB-L1...The locking arm is held in the locked position by spring force and is unlocked by solenoid force (closed-circuit current principle, mechanically locked).
Door stopA mechanical door stop is permanently integrated into the evaluation module of the MGB. A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Monitoring outputs
OTBolt tongue inserted into the evaluation module
OLGuard locking solenoid in locked position
OIDiagnostics, there is a fault
Key-operated switch
S1Key-operated rotary switch with two positions (form L, 90°). The switch latches in both positions, but it can be removed only in position 0.
Pushbutton
S2One NO contact, illuminated
S3One NO contact, illuminated
Lens setThe color of the pushbutton can be selected using the lens set included (five colors). Item no.: 120344 (see Accessories) Escape releaseThe escape release enables people accidentally shut in to open the guard locked door from the danger zone. NoticeOnly numbered connecting cables may be used for this MGB set. (See Accessories) Dimension drawing Dimension drawing Plug connector RC18 MGB: The MGB-System in use MGB: MGB Impact test MGB: Mounting left door, with escape release Mounting left door, without escape release Mounting right door, without escape release MGB: Changing single wiring (AP) to series wiring (AR) MGB: Deactivating guard lock monitor MGB: Activating guard lock monitor MGB: Activating release monitoring MGB: Change color-lens push button Dimension drawingDimension drawingPlug connector RC18 Technical data Locking module MGB-L1-ARA-AN3A1-S1-L-157849 (Order no. 157849) Mechanical values and environment
Housing material Reinforced plastic, die-cast zinc nickel-plated, stainless steel
Weight
Net 0,75 kg
Ambient temperature
At UB = 24V DC -20 ... 55 °C
Degree of protection IP54
Mechanical life 1 x 106
In case of use as door stop, and 1 Joule impact energy 0,1 x 106
Installation orientation Door hinge DIN left
Switching frequency 0,25 Hz
Connection Plug connector RC 18
Guard locking principle Closed-circuit current principle
Locking force FZh 2000 N
Electrical connection ratings
Utilization category according to EN 60947-5-2
DC-13 24V 200mA
Rated insulation voltage Ui 30 V
Rated impulse withstand voltage Uimp 1,5 kV
Degree of contamination (external, according to EN 60947-1) 3
Connection cross-section
(Rigid/flexible) 0,13 ... 1,5 mm? (AWG 24 ... AWG 16)
(Rigid/flexible) with cable end sleeve according to DIN 46 228/1 0,25 ... 1,5 mm?
(Rigid/flexible) with cable end sleeve with collar according to DIN 46 228/1 0,25 ... 0,75 mm?
Safety class III
Discrepancy time
Between FO1A and FO1B max.10 ms
Risk time according to EN 60947-5-3 max.350 ms
Transponder coding Unicode
Controls and indicators
Switching voltage UA V
Switching current 1 ... 10 mA
Breaking capacity max.0,25 W
Power supply LED 24 V DC
Solenoid control input IMP1, IMP2, IMM
Test pulses max.5 ms
Test-pulse interval min.100 ms
Power supply UB
Operating voltage DC
UB 24 V DC -15% ... 10%
Current consumption
IUB max.80 mA
Power supply UA
Operating voltage DC
UA 24 V DC -15% ... 10%
Current consumption
IUA max.375 mA
Safety outputs FO1A, FO1B
Test pulses max.1 ms
Test-pulse interval min.100 ms
Type of output Semiconductor outputs, p-switching, short circuit-proof
Output voltage
UFO1A /UFO1B HIGH UB-2V ... UB V DC
UFO1A /UFO1B LOW 0 ... 1 V DC
Output current
Per safety output FO1A / FO1B 1 ... 200 mA
Monitoring outputs OD, OT, OL, OI
Type of output Semiconductor outputs, p-switching, short circuit-proof
Output voltage UA-2V ... UA V DC
Output current max.50 mA
Other
Additional feature Incl. cover set ID. No. 120344
Product version number V3.0.3
Reliability values according to EN ISO 13849-1
Monitoring of guard locking and the safety guard position
Category 4
Performance Level PL e
PFHD 3.7 x 10-9
Control of the guard locking
Category 4
Performance Level PL e
PFHD 2.8 x 10-9
Mission time 20 y
Escape release MGB-E-A-100465 (Order no. 100465) Mechanical values and environment
Housing material Die-cast zinc/stainless steel powder-coated
Weight
Net 0,75 kg
Ambient temperature -20 ... 55 °C
Mechanical life 1 x 106
Installation orientation Any
Other
Product version number V2.0.0
Handle module MGB-H-AA1A3-L-111158 (Order no. 111158) Mechanical values and environment
Housing material Reinforced plastic, die-cast zinc nickel-plated, stainless steel
Weight
Net 1,00 kg
Ambient temperature -20 ... 55 °C
Degree of protection IP65
Installation orientation Door hinge DIN left
Other
Additional feature With automatic lockout mechanism
Product version number V3.0.0
Components 157849 Locking module MGB-L1-ARA-AN3A1-S1-L-157849
  • Guard locking with guard locking monitoring
  • Can be connected in series with other AR devices (e.g. CES-AR and CET-AR)
  • Key-operated rotary switch (form L, 90°)
  • Two pushbuttons (illuminated)
  • With lens set, six pcs.
  • With plug connector RC18
  • Unicode
  • IP 54
100465 Escape release MGB-E-A-100465
  • Escape release from the danger zone
  • Door handle signal red
  • Extended actuation axis for thicker doors (available optionally)
111158 Handle module MGB-H-AA1A3-L-111158
  • Intelligent bolt tongue
  • Fold-out lockout mechanism
  • Second automatically extending lockout mechanism
  • Door handle
''