Описание

  • Guard locking with guard lock monitoring
  • Emergency stop according to ISO 13850, illuminated
  • 2 illuminated pushbuttons
  • Including adhesive labels
  • Connection via M12 plug
  • Pre-assembled on mounting plates
  • Unicode
Dimension drawing Wiring diagram MGB: The MGB-System in use MGB: MGB Impact test MGB: Mounting left door, with escape release Mounting left door, without escape release Mounting right door, without escape release MGB: Deactivating guard lock monitor MGB: Activating guard lock monitor MGB: Activating release monitoring MGB: Change color-lens push button Dimension drawingWiring diagram Technical dataApprovals Mechanical values and environment
Housing material Reinforced plastic, die-cast zinc nickel-plated, stainless steel
Weight
Net 3,1 kg
Ambient temperature
At UB = 24V DC -20 ... 55 °C
Degree of protection IP54
Resilience to vibration In accordance with EN 60947-5-3
Mechanical life 1 x 106
In case of use as door stop, and 1 Joule impact energy 0,1 x 106
Installation orientation Door hinge DIN left
Reaction time
Guard locking max.250 ms Switch-off time
Emergency stop / machine stop max.100 ms Switch-off time
Door position max.250 ms Switch-off time
Bolt position max.250 ms Switch-off time
Switching frequency 0,25 Hz
Connection
M12 Power, A-coded
M12 Power, A-coded
Ethernet/IP cable, Cat. 5e min. M12 D-coded, screened
M12 D-coded, screened
Guard locking principle Open-circuit current principle
Locking force FZh 2000 N
Electrical connection ratings
Current consumption max.500 mA
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 0,5 kV
Maximum feed-in current in the connection block
X1, X2 max.4000 mA
EMC protection requirements In accordance with EN 61000-4 and EN 61326-3-1
Degree of contamination (external, according to EN 60947-1) 3
Connecting cable
Ethernet Ethernet/IP cable, Cat. 5e min.
Safety class III
Transponder coding Unicode
Power supply X1
Operating voltage DC
L1 24 V DC -15% ... 10%
Auxiliary voltage DC
L2 24 V DC -15% ... +10%
Fusing
external min.1 A Slow blow
Power supply X2
Operating voltage DC
L1 24 V DC -15% ... 10%
Auxiliary voltage DC
L2 24 V DC -15% ... +10%
Work area
Assured switch-off distance Sar max.65 mm
Interface, bus
Data interface
Data protocol
Bus protocol Ethernet/IP
Safety protocol CIP Safety
Controls and indicators
Belegungsschema B0
Belegungsschema L1
Position 1
Ausfuhrung Emergency stop illuminated
Einlegeschild
Extras With adhesive ring
Farbe
Schaltelement 2 pos. driven NC
Position 2
Ausfuhrung Illuminated push buttons
Einlegeschild
Extras
Farbe
Schaltelement 1NO
Position 3
Ausfuhrung Illuminated push buttons
Einlegeschild
Extras
Farbe
Schaltelement 1NO
Other
Additional feature Incl. cover set ID. No. 120344
Product version number V1.2
Slide-in label 2 pcs. without marking
Reliability values according to EN ISO 13849-1
Monitoring of guard locking and the safety guard position
Category 4
Performance Level PL e
PFHD 3.37 x 10-9
Diagnostic Coverage (DC) 99
Emergency stop
B10D
Emergency stop 0.1 x 106
Emergency-stop evaluation
Category 4
Performance Level PL e
PFHD 3.05 x 10-9
Performance Level PL e
Category 4
PFHD 4.91 x 10-9
Safety Integrity Level SIL 3 (EN 62061:2005)
Mission time 20
''