Описание

Multi-bank type with camera function
Model SZ-V32X*1
Type Multi-bank Type
Detection capability Minimum detectable object size Diameter: 20, 30, 40, 50, 70, 150 mm (depends on the setting), Reflectance: 1.8% min., Speed: 1.6 m/s max.*2
Detectable angle 190° (-5° to 185°)
Response time (ON to OFF) Standard Mode Scan Cycle A 160 ms (2 scans) to 1280 ms (16 scans)*3
Scan Cycle B 168 ms (2 scans) to 1344 ms (16 scans)*3
Scan Cycle C 176 ms (2 scans) to 1408 ms (16 scans)*3
High Speed Mode Scan Cycle A 80 ms (2 scans) to 640 ms (16 scans)*3
Scan Cycle B 84 ms (2 scans) to 672 ms (16 scans)*3
Scan Cycle C 88 ms (2 scans) to 704 ms (16 scans)*3
Response time (OFF to ON) Response time of ON to OFF + 150 ms
Protection zone Minimum detectable object size: 70 / 150 mm Standard Mode: 8.4 m / High Speed Mode: 5.7 m
Minimum detectable object size: 50 mm Standard Mode: 5.6 m / High Speed Mode: 3.8 m
Minimum detectable object size: 40 mm Standard Mode: 4.3 m / High Speed Mode: 2.9 m
Minimum detectable object size: 30 mm Standard Mode: 2.9 m / High Speed Mode: 2.0 m
Minimum detectable object size: 20 mm Standard Mode: 1.6 m / High Speed Mode: 1.1 m
Warning zone Minimum detectable object size: 70 / 150 mm Standard Mode: 26 m / High Speed Mode: 23 m*4
Minimum detectable object size: 50 mm Standard Mode: 25 m / High Speed Mode: 21 m*4
Minimum detectable object size: 40 mm Standard Mode: 24 m / High Speed Mode: 20 m*4
Minimum detectable object size: 30 mm Standard Mode: 23 m / High Speed Mode: 18 m*4
Minimum detectable object size: 20 mm Standard Mode: 21 m / High Speed Mode: 15 m*4
Additional safety distance 100 mm*5
Maximum measurement distance 60 m*6
Maximum number of banks Max. 32 banks
Multiple scanner heads Max. 3
Camera Monitor area: over 190° (-5° to 185°)*7
Display QVGA 2.2 inch colour LCD
Light source Type, wavelength Infrared laser diode, 905 nm
Laser class IEC Class 1 IEC / EN 60825-1
FDA Class 1 FDA 21 CFR 1040.10, 1040.11 (Laser Notice No.50)*8
JIS Class 1 JIS C6802
Control output (OSSD output) Output type PNP or NPN transistor output (settings configurable with SZ-V Configurator)
Number of outputs 2 outputs
Max. load current 500 mA*9
Residual voltage Max. 2.5 V (with a cable length of 5 m)
OFF-state voltage Max. 2.0 V (with a cable length of 5 m)
Leakage current Max. 1 mA*10
Max. capacitive load 2.2 µF (with a load resistance of 100 ?)
Load wiring resistance Max. 2.5 ?
Input (safety-related) PNP ON-voltage: 10 to 30 V, OFF-voltage: Open or 0 to 3 V, Short-circuit current: Approx. 2.5 mA (EDM input: Approx. 10 mA)
NPN ON-voltage: 0 to 3 V, OFF-voltage: Open or 10 V to Power voltage, Short-circuit current: Approx. 2.5 mA (Approx. 10 mA for EDM)
Non safety-related output (AUX output) Output type Transistor output (PNP or NPN, settings configurable with SZ-V Configurator)
Number of outputs 4 outputs
Max. load current 50 mA
Residual voltage (during ON) Max. 2.5 V (with a cable length of 5 m)
Muting lamp -
Interface USB USB 2.0
Ethernet Standard -
Transmission rate
Cable
Connector
Networking/data output
Cable length Power cable 30 m or less*11
Connection cable 20 m or less each*12
Ethernet cable -
Approved standards EMC EMS IEC61496-1, EN61496-1, UL61496-1 (Type3 ESPE)
EMI EN55011 Class A, FCC Part15B Class A, ICES-003 Class A
Safety IEC61496-1, EN61496-1, UL61496-1 (Type3 ESPE), IEC61496-3, EN61496-3 (Type3 AOPDDR), IEC61508, EN61508, IEC62061, EN62061 (SIL2/SILCL2), EN ISO13849-1:2015 (PLd, Category3), IEC61784-3-3, UL508, UL1998, CSA C22.2 No.14, CSA C22.2 No.0.8
Rating Power consumption 11.8 W (without load), 55.0 W (with load)*13
Power voltage When using a converter power supply: 24 VDC ±10 %, Ripple (P-P) 10 % or less When using a battery: 24 VDC +20 % /-30 %
Environmental resistance Enclosure rating IP65 (IEC60529)
Ambient light Incandescent lamp: 1,500 lux or less*14
Operating ambient temperature -10 to +50 °C (No freezing)
Storage temperature -25 to +60 °C (No freezing)
Operating relative humidity 35 to 85 % RH (No condensation)
Storage relative humidity 35 to 95 % RH
Vibration resistance 10 to 55 Hz, Double amplitude 0.7 mm, 20 sweeps in each of the X, Y, and Z directions
Shock resistance 100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions
Material Scanner head Main unit case Magnesium
Window Polycarbonate, PEI
Indicator part Aluminum, PES*7
Display unit case Magnesium, PPS, Polycarbonate
System memory Aluminum, PPE
Weight Approx. 2,100 g
*1 Integrated models include display unit, scanner head, system memory and a connection cable (SZ-VS005). *2 If the object to be detected moves perpendicular to the detection plane, SZ-V cannot detect the object moving at speed over 1.6 m/s, regardless of the encoder setting. *3 The response time, protection zone, and warning zone are affected by the operation mode. *4 20% or more reflectance is necessary for the minimum detectable object in the warning zone. *5 If there is a highly reflective background within 1.5 m from the boundary of the protection zone, 200 mm must be added as supplementary necessary distance to the protection zone when calculating the minimum safety distance. *6 Even when using the network data output, the maximum measured output distance is 60 m. *7 Only applicable for the type with a camera. *8 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50. *9 The load current calculation of the OSSD output and AUX output is 1.5 A or less when using one scanner head, 1.0 A or less when using two scanner heads, and 0.5 A or less when using three scanner heads. *10 Includes when the power is OFF. *11 10 m or less when supplying power from a battery. *12 When supplying power from a battery, the length of each connection cable should be 10 m or less when using two scanner heads, and 5 m or less when using three scanner heads. *13 When using the SZ-V with series connected sensor heads, it is necessary to add 9.4 W per scanner head. Also, power consumption may temporarily be higher (maximum 3.6 W). Power consumption will be within the specification after SZ-V moves to normal operation. *14 An ambient light source should not be located within ±5° of the detection plane.
''