Описание

Head: 2-axis standard model without monitor camera
Model LS-9030D
Type Head: 2-axis small-diameter model
Measurement range o0.3 mm to o30 mm
Smallest detectable object 0.3 mm
Repeatability ±0.1 µm*1
Measurement accuracy ±2 µm*2
Sampling cycle 16,000 samples/sec.*3
Light source InGaN green LED
Monitor camera Not provided
Environmental resistance Enclosure rating IP67 (including connector part)
Ambient light Incandescent lamp/Fluorescent lamp: 3,000 lux or lower
Ambient temperature 0 to +50 °C
Relative humidity 20 to 85 % RH (No condensation)
Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions
Shock resistance 15 G/6 ms
Material Aluminum
Weight Approx. 9 kg
*1 A ±2? margin of error when measuring a o10 mm rod in the centre of the measurement area using outer diameter mode with the average measurement number set as 2,048 times. *2 Margin of error when a moving o10 mm rod is measured in the 10 mm x 10 mm measurement area. *3 The sampling cycle is changed by the number of OUT set, and by the use of the mutual interference prevention function.
''