Описание

Main Unit
Model SJ-W100
Static eliminator connection Supported devices SJ-G (V/R) Series
Maximum number of connectable cables 16 (8/output)
Output voltage 36 VDC ? 2 outputs (modular collector)
Control input NPN open collector or no-voltage contact signal, 17 inputs
Alarm output Alarm strobe output unit, alarm output main unit, alarm output 7, maximum NPN open-collector output: 50 mA (30 V or less), residual voltage: 1 V or less (N.C.)
Unit ID number output 4, maximum NPN open-collector output: 50 mA (30 V or less), residual voltage: 1 V or less (N.O.)
RS-232C interface Operation and warning status output and static elimination control input (baud rate: fixed to 9,600 bps)
Major features Operation and warning status display, warning output, static elimination stop input, automatic recognition
Rating Power voltage 100 to 240 VAC, 50/60 Hz*1
Overvoltage category II
Pollution level 2
Power consumption 170 VA
Environmental resistance Ambient temperature 0 to +40 °C
Relative humidity 35 to 85 % RH (No condensation)
Weight Approx. 1.3 kg
*1 Ratings of the included AC cable: rated voltage: 125 VAC, rated current: 7 A
''